Insulation Terminal Application Precautions
Nowadays, Cable Lugs has been applied to all walks of life, but when we apply the insulating terminal, there are some aspects that need to be paid attention to. Let me explain to you some application precautions of the insulating terminal.
First of all, when we apply the insulating terminal, we must first have a certain understanding and familiarity with the insulating terminal to be operated, so that we can perform the correct application operation of the insulating terminal. Because some insulating terminals that do not have the function of preventing misoperation will be marked by manufacturers, so when we choose the insulating terminal for application, we must choose the appropriate one to ensure that the connection is correct and normal during the application process. Of course, special attention should be paid to avoid mis-insertion of some pin sockets, which will cause damage to the entire insulating terminal and dangerous situations such as contacts. Therefore, when we apply the insulating terminal, we should understand the corresponding operating regulations and make detailed operation process confirmation to ensure that the application of the insulating terminal is correct. Of course, we also need to conduct certain inspections on the insulated terminals we are going to use to ensure that they are not damaged and are qualified in terms of quality and performance.
Let me explain to you two ways to connect insulated terminals. The first is the insulated terminal termination. When terminating the insulated terminals, we must strictly follow the standard operation requirements of the termination and perform the corresponding inspections before terminating at the corresponding node positions. During the termination process, the thickness of the insulation layer between the selected cable conductors should match the contact pieces, and the cable core should also match the contact end.
Another is the welding method of the insulated terminal. Generally, the welding method requires the selection of a soldering iron of corresponding power according to the diameter of the wire. During the welding process, be careful not to let the flux flow into the insulated terminal, which will cause the resistance of the entire insulated terminal to decrease.
Of course, if the insulating end is in a separated state before it needs to be connected, we need to install some protective caps on the insulating end or take some other dust-proof measures, so that the insulating end can be effectively kept in a clean state. Of course, if the insulating end is not separated for a long time after being connected, you can put a fuse between the plug and the socket to ensure the safety and stability of the insulating end. It is also necessary to try to ensure that the axis of the plug and the socket overlap, so as to prevent the cable from sagging and causing damage to the entire insulating end connector.
If the insulating end is not dust-proof during the storage process, it should be cleaned when it is used later. Wipe the insulating end with some silk cloth dipped in anhydrous ethanol. After cleaning, it can be put into normal use. Of course, some chemical solvents that may affect the insulating end are prohibited from being used to clean the insulating end. Some acetone chemical solvents will have a harmful effect on the insulating end.
Finally, for safety reasons, it is forbidden to energize the insulating terminals before they are fully connected or locked. After using threaded installation insulating terminals, it is necessary to add anti-loosening devices to the insulating terminals with this connection method to ensure the safety of electrical use of the insulating terminals.